Servicing, faults and parts
I can't smell ozone in my sauna any more. Is the ozonator still producing ozone?
Use the glove test on a Salvagente ozone sauna: with the oxygen concentrator running and ozone on, hold a latex glove in front of the ozone outlet for a few seconds. Ozone oxidises latex, so a hole should appear. Do not test by smell — ozone is toxic to inhale and operators become desensitised to it.
Do not test by smell
People who are around ozone daily stop noticing the sharp, sulphurous smell, so a weak smell does not mean the generator has failed, and a strong one is not a measurement. Ozone is also toxic to the lungs, and our guidance is not to lean in, put your face into the cabinet or open the doors while ozone is running — which is exactly what a smell test asks you to do.
Bear in mind too that the generator stops producing five minutes before the session ends, and ozone’s half-life in the hot sauna is roughly 10 to 20 minutes. Little is left when you open the doors, which is by design.
The glove test
- Confirm the oxygen concentrator is switched on and running, and that no pipe between the concentrator and the sauna is pinched, blocked or disconnected. A test run with the concentrator off tells you nothing.
- With the ozone on, hold a latex glove in front of the ozone outlet for a few seconds.
- Ozone is a strong oxidant — it strips electrons from whatever it meets — and latex is not an ozone-resistant material, so a hole should appear in the glove. No hole after a fair exposure means no meaningful ozone output.
What a positive test does and does not tell you
A hole in the glove means the generator is producing ozone. It does not tell you how much, and it is not a calibration.
What the generator should be doing is settled: 500 mg/h at full output, stepped by 10 per cent at each of the ten display levels, on a constant 2 l/min oxygen feed, giving about 47 ppm across the whole air volume inside the sauna. Confirming that in the field is another matter — measuring real output needs a laboratory-grade analyser, which is worth remembering if anyone offers to “calibrate” your generator.
If the glove shows no damage, work through the no-ozone checks: the concentrator, the pipework, and the internal fitting that holds the ozone pipe.